ICRS Intacs (Intrastromal Corneal Ring)

///ICRS Intacs (Intrastromal Corneal Ring)

Intacs Implantation Instruments

2021-10-18T08:38:31+00:00

SPECS

Surgical Instrumental for Intacs® SK (Optical area 6 mm.)
Product DescriptionIntacs® SK Surgical Instruments consist of a series of ophthalmic instruments that are designed for the placement
of Intacs® SK (optical area of 6mm). Supplied with no sterilization.
intacts_5intacts_6
intacts_7
intacts_8
ReferenceKV10445KV10478-2KV10606KV1160
InstrumentIntacs® SK ForcepsIntacs® SK Vacuum Centering Guide, SlopedPocketing HookIntacs® SK Symmetric Glide
MaterialTitaniumStainless steelTitaniumTitanium
Characteristics and indications· Notched tip.
· Facilitates easy removal of the segments from the carrier.
Port for attachment to a vacuum source.
· Equipped with fins on the bottom.
· Centers and stabilizes the Corneal Separators onto the
cornea during the dissection
of the intrastromal tunnels
· Initiates the delamination of the stroma.· Bifurcated glide.
· Guides in both the CW and CCW Corneal Separators.
CE
intacts_1
intacts_2intacts_3
ReferenceAT11209-1AT11209-2AT11210AT11211
InstrumentSK Corneal Separator, CW 0.6 mmSK Corneal Separator CCW 0.6 mmSK Inspection GaugeProcedure Marker
MaterialStainless steelUltemStainless steel
Use indications· Also known as Corneal Dissectors.
· Creates a CW and CCW annular subsurface tunnel.
· Inspects the concentricity
and planarity of the 0.6mm Corneal Separator blades.
· Aligns the Vacuum Centering Guide.
Additional InstrumentsDescription and References
- Diamond Knife, 15o angled blade - Ref: DK-5-330-1.
- Sterilization Tray - Ref: Intacs 17110-Intacs SK 4710-A.
- Sinskey Hook - Ref: 6-251.
- Bonn Suturing Forceps - Ref: 2-110.
- Ring Marker with Cross Hairs, 11mm Zone - Ref: 9-789W-1.
- Kratz Barraquer Speculum - Ref: 9-556F.
- Vacuum system - Ref: KV2000.
- Vacuum tubings - Ref: 7K5000.
CE

MORE INFORMATION

Technical Sheets
Intacs implants

Intacs

2024-11-13T14:33:12+00:00

SPECS

Brand nameIntacs®
ModelINTACS®SK(optic zone of 6.0 mm)
DefinitionIntrastromal Corneal Ring (ICRS)
IndicationsConsult nomogram for each case.
Customized advice: keratoconus@ajlsa.com
Product descriptionIntacs® SK are intrastromal corneal rings designed to treat keratoconus. Once implanted in the corneal stroma, it regularizes corneal deformities, restoring functional vision to the patient.
MaterialPoly-methylmethacrylate (PMMA)
Sterilization methodEthylene oxyde (ETO).
SupplySterile packaged single ring
Shelf-life5 years
CE0318

INTACS® SK CORNEAL IMPLANTS

INTACS® SK CORNEAL IMPLANT
THICKNESS-ARCREFERENCE
0,250mm-90ºISKS-250-90
0,300mm-90ºISKS-300-90
0,350mm-90ºISKS-350-90
0,400mm-90ºISKS-400-90
0,450mm-90ºISKS-450-90
0,300mm-130ºISKS-300-130
0,350mm-130ºISKS-350-130
0,400mm-130ºISKS-400-130
0,450mm-130ºISKS-450-130
0,210mm-150ºISKS-210-150
0,250mm-150ºISKS-250-150
0,300mm-150ºISKS-300-150
0,350mm-150ºISKS-350-150
0,400mm-150ºISKS-400-150
0,450mm-150ºISKS-450-150
0,500mm-150ºISKS-500-150
*OTHER THICKNESS AVAILABLE PER REQUEST

MORE INFORMATION

TECHNICAL SHEETS
CLINICAL STUDIES
Web Intacs

NOMOGRAMA KERATOCONUS 

El nomograma desarrollado por AJL Ophthalmic, S.A. le ayudara con todos los cálculos necesarios en la elección de la utilización de segmentos Ferrara e Intacs para el tratamiento de diversas patologías.

NOMOGRAM ACCESS